Products+

Contact Us

UPVC Conduits for Underground Telecommunication Cable

PVC-U electrical and telecommunication conduits are designed to protect and carry both fibre optic and other telecommunication cables in a wide range of buried and underground installations. PVC-U is the most commonly used material for electrical conduits due to its lightweight, ease of assembly and non-conductivity.

  • 1.Delivery: 10-30 days depending on the total quantity.
  • 2.Packing: 4m or 6m/ Pcs for straight, with plain ends or SCJ end.
  • 3.CO (Certificate of Origin): China, CO could be provided by free.
  • 4.Products Inspection: Raw material, production process, delivery or third-party factory inspection
  • 5.MOQ: Trial Order or 1*20ft containers by mixed loading.

Quick Details of Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

Products details information Company/Factory Strength
Product name Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable Production Capacity 120*40ft containers/month
Brand Bingo pipeline(Customer brand is available) Sample Free sample could be provided
Dia Ranges DN20-300mm(1/2 inch-12 inch) Quality QA & QC system, Ensure traceability of each process
Application Cable, Telecommunication Cable... Warranty 50 years with normal use
Raw material U PVC... Certificates ISO9001, OHSAS 18001, ISO14001,CE...
Standards NEMA TC 2 : 2003, EPC-40-PVC, EPC-80-PVC, NEMA TC 6 & 8 ... Delivery time 5-30 days, depending on the quantity
Length 4m or 6m/ length(customizable) Test/Inspection National Standard Laboratory/ Pre-delivery inspection
Place of Origin China Service Research, Design, manufacture, Test, Sales, Solution Providing, After-sale service
Pressure Class Non Pressure Management Effective 8S Management System
Color Orange, others colors is option No. of employees More than 300 people
Matching products: U PVC fittings, Solvent Cement fittings, Rubber Ring Joints, Flanges, Glue and tools, etc.

Welcome customers to visit the factory, or third party factory inspection is acceptable.

Description of Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

The UPVC pipes used for electrical and telecommunication conduits have different colors.

Orange: Electrical conduits installed under ground

Grey: Electrical conduits installed above ground

White: Data and telecommunications conduits

PVC-U electrical cable ducts are intended for durable underground installation using conventional open cut trench methods, to identify and protect contained underground electrical cables. Coloured orange, they are available in 6m socketed lengths and nominal diameters ranging from 32mm to 150mm.

We also provide a wide variety of duct bends made out of PVC-U and are available in all major diameters, lengths and radii, and the couplers, saddles, ends fittings are available for choice.

The U PVC pipes used for electrical conduit includes light duty, medium duty and heavy duty, available in the length 4m/length or 6m/ length, with the socket end. Heavy duty conduit offers a higher impact and compression resistance when compared medium duty electrical conduit and light duty conduit.

Advantages of Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

1.Strong resistance to stress. The high-resistance heavy-duty conduit series and the high-impact medium-duty conduit series can withstand strong pressure, so it can be applied in concrete, not afraid of cracking under pressure.

2.Corrosion-resistant and insect-resistant. PVC pipe has excellent acid and alkali resistance. At the same time, because the PVC pipe does not contain plasticizer, it is free of pests and rodents.

3.Good flame retardant performance. Avoid the spread of fire along the pipeline; in case of fire, it can effectively protect the line for a long time, ensure the operation of the electrical control system, and facilitate the evacuation of personnel.

4.Strong insulation performance. Can withstand high voltage without being broken down, effectively avoiding metal and electric shock hazards.

5.Not easy to age. Stabilizers are added to improve the stability to heat and light.

6.Light weight, easy transportation and construction, and low cost.

7.The seismic resistance and anti-uneven settlement is good, no need to encapsulate and pour concrete on the construction site.

Specification of Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

Specification dn*en (mm)  Mean Outside Diameter de (mm) Nominal wall thickness en (mm) Solvent Cement Joints (SCJ) Rubber Ring Joints (RRJ)
Depth of Socket L (mm) Mean inner diameter in the middle of socket di (mm) Minimum socket length Amin (mm) First stage minimum length of socket Bmin (mm) Minimum ID of socket in second stage dimin (mm)
dn Limit Deviation Thickness Limit Deviation min (mm) max (mm)
50*2.0 50 -0.3 +0.6 2.0 -0.2 +0.3 60 49.8 50.7 - - -
50*2.8 50 -0.3 +0.6 2.8 -0.3 +0.3 60 49.8 50.7 - - -
50*5.0 50 -0.3 +0.6 5.0 -0.5 +0.5 60 49.8 50.7 - - -
63*5.0 63 -0.3 +0.6 5.0 -0.5 +0.5 65 62.8 63.7 - - -
75*2.3 75 -0.3 +0.6 2.3 -0.2 +0.2 70 74.8 75.7 - - -
75*2.8 75 -0.3 +0.6 2.8 -0.3 +0.3 70 74.8 75.7 - - -
75*5.0 75 -0.3 +0.6 5.0 -0.5 +0.5 70 74.8 75.7 - - -
90*2.8 90 -0.3 +0.6 2.8 -0.3 +0.3 70 89.8 90.7 - - -
90*3.2 90 -0.3 +0.6 3.2 -0.3 +0.3 70 89.8 90.7 - - -
90*4.5 90 -0.3 +0.6 4.5 -0.4 +0.4 70 89.8 90.7 - - -
110*3.0 110 -0.4 +0.8 3.0 -0.3 +0.3 - - - 100 60 111.0
110*4.0 110 -0.4 +0.8 4.0 -0.4 +0.4 - - - 100 60 111.0
110*5.0 110 -0.4 +0.8 5.0 -0.5 +0.5 - - - 100 60 111.0
110*7.0 110 -0.4 +0.8 7.0 -0.7 +0.7 - - - 100 60 111.0
160*3.2 160 -0.5 +1.0 3.2 -0.3 +0.3 - - - 120 60 161.2
160*4.0 160 -0.5 +1.0 4.0 -0.4 +0.4 - - - 120 60 161.2
160*5.0 160 -0.5 +1.0 5.0 -0.5 +0.5 - - - 120 60 161.2
160*8.0 160 -0.5 +1.0 8.0 -0.8 +0.8 - - - 120 60 161.2
167*5.0 167 -0.5 +1.0 5.0 -0.5 +0.5 - - - 140 60 168.5
167*6.0 167 -0.5 +1.0 6.0 -0.6 +0.6 - - - 140 60 168.5
167*8.0 167 -0.5 +1.0 8.0 -0.8 +0.8 - - - 140 60 168.5
167*8.5 167 -0.5 +1.0 8.5 -0.8 +0.8 - - - 140 60 168.5
192*5.8 192 -0.5 +1.0 5.8 -0.6 +0.6 - - - 160 60 193.8
192*6.5 192 -0.5 +1.0 6.5 -0.6 +0.6 - - - 160 60 193.8
192*7.5 192 -0.5 +1.0 7.5 -0.7 +0.7 - - - 160 60 193.8
192*8.5 192 -0.5 +1.0 8.5 -0.8 +0.8 - - - 160 60 193.8
200*4.0 200 -0.5 +1.0 4.0 -0.4 +0.4 - - - 180 60 202.0
200*5.0 200 -0.5 +1.0 5.0 -0.5 +0.5 - - - 180 60 202.0
200*6.0 200 -0.5 +1.0 6.0 -0.6 +0.6 - - - 180 60 202.0
200*8.0 200 -0.5 +1.0 8.0 -0.8 +0.8 - - - 180 60 202.0
200*9.0 200 -0.5 +1.0 9.0 -0.9 +0.9 - - - 180 60 202.0
200*10.0 200 -0.5 +1.0 10.0 -0.9 +0.9 - - - 180 60 202.0

Other specifications have not been shown on our dimension chart, please CONTACT US for more information

Applications of Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

  • Telecommunication duct
  • Telecommunication repair sleeve
  • Used in Telephone Cables
  • High voltage underground cables
  • Street and housing power supplies
  • Factory and industrial applications
  • Traffic signal cable protection
  • Construction and transformation of urban power grids.
  • Urban municipal renovation project.
  • Traffic, road and bridge construction.
Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable
U PVC Conduit Or Duct High Voltage Cable U PVC Conduit Or Duct for Cables
Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable
U PVC Conduit Or Duct for Buried Cable U PVC Conduit Or Duct for Cables

Unplasticised polyvinyl chloride(U PVC) conduits for Underground Telecommunication Cable

Write Down Your Question

We are not only a product manufacturer, also a solution provider, whether you have a Question or Request For Quotations, we're here to help.

Home Tel Mail Inquiry WhatsApp